DETERMINING FLAKINESS INDEX - ftp.dot.state.tx.us DETERMINING FLAKINESS INDEX TxDOT Designation: Tex-224-F Effective Dates: December 2004–July 2016. 1. SCOPE 1.1 Use this test method to determine the percentage of particles in a coarse aggregate material that have a thickness (smallest dimension) of less than one-half of the nominal size. Flakiness Sieve Set, टेस्टिंग सिव, परीक्षण चलनी - Zeal ... Zeal International offering Flakiness Sieve Set, टेस्टिंग सिव, परीक्षण चलनी in New Delhi, Delhi. Get best price and read about company and get contact details and address. | ID: 14281808797 Utest Material Testing Equipments by Utest Material ... - Issuu The accuracy of the slot size is better than 0.1 mm. UTA-0410 Flakiness Index Sieve Set consists of 7 sieves. UTA-0365 For sample preperation 6.3, 10, 14, 20, 28, 37.5, 50 and 63 mm aperture sizes ... AGGREGATE TEST EQUIPMENTS AGGREGATE TEST EQUIPMENTS
The Flakiness Index of an aggregate is determined using a gauge with slots of ... appropriate slot or slots for the individual size fraction expressed as a ...
Flakiness and Elongation - pcte.com.au The accuracy of the slot size is better than 0.1 mm. UTA-0410 Flakiness Index Sieve Set consists of 7 sieves. For sample preparation 6.3, 10, 14, 20, 28, 37.5, 50 and 63 mm aperture sizes test sieves should be ordered separately. SD 203 Method of Test for Flakiness Index plate. The size of the slots required for each fraction is given in table 1 below. NOTE: If the material retained on any one of the sieves comprises less than 4% of the total weight of the sample, that material shall be omitted from the flakiness index test. If a 5/8” Flakiness Index Sieve Sets BS - Flakiness Index - Utest
of aggregate and binder, for example, the work ability of concrete, or the stability of mixtures that depends on the interlocking of particles.
Grid Sieve 20mm Slot Width for EN Aggregate Flakiness Test. « return. ... Passing size - 5 mm Retained size - 4 mm Slot width - 2.5 mm more. determination of flakiness index test. - slideshare.net THEORY Flakiness index Aggregate particles are classified as flaky when they have a thickness (smallest dimension) of less than 0.6 of their mean sieve size. The flakiness index of an aggregate sample is found by separating the flaky particles and expressing their mass as a percentage of the mass of the sample tested. Flakiness Sieve Series Bs Standard - Testmak Material Test ... The Flakiness Sieve Series (Bs Standard) dimensions of each sieve comply with the relevant international standard, manufactured from heavy gauge steel sheet and coated with electrostatic paint. The accuracy of the slot size is better than 0.1 mm. TMA-1450 Flakiness Index Sieve Set consists of 7 sieves. For sample preperation 6.3, 10, 14, 20, 28 ...
To evaluete the thickness and the elongation index of the aggregates particles, thickness gauge code 47-D0540 and length gauge code 47-D0541 can be used. See link to other ... Flakiness sieve 4.9x30 mm slot 47-D0415/2. Flakiness sieve ...
INDIANA DEPARTMENT OF TRANSPORTATION OFFICE OF …
For determining flakiness index. Particle is flaky when its thickness (smallest dimension) is less than 0.6 of the mid-size of the sieve fraction. Gauge has seven, labeled slots for manual evaluation of particles in the seven openings. The mass of all flaky particles (passing appropriate slots) as percent of the sample is the flakiness index.
Flakiness and Elongation - pcte.com.au Flakiness and Elongation Flakiness Index Sieve Set UTA-0410. When an aggregate particle has a thickness less than 0.6m of its mean sieve size, it is considered flaky. The aggregate to be classified is separated into seven sieve fractions from 6.3 to 63 mm and each fraction is examined separately. AGGREGATE FLAKINESS INDEX VALUE (IS:2386-Part 1-1963 ... Objective For determination of flakiness index of coarse aggregate, where the size of the coarse aggregate are larger than 6.3mm . Reference Standards IS : 2386 (Part I) – 1963 – Method of test for aggregates for concrete (Part I) Particle size and shape. INDIANA DEPARTMENT OF TRANSPORTATION OFFICE OF MATERIALS ... 1.1 This test method describes a procedure to determine the Flakiness Index (FI) of aggregates. The FI is used as a design input to determine the rate of application of aggregate and asphalt material for seal coats. 1.2 The flakiness index is a measure of the cubical shape of the aggregate which is 1223.1 1223.2 APPARATUS A. conforming to the design and ...
Method B3T: Tentative method for the determination of the Flakiness ... The Flakiness Index of a coarse aggregate is determined by gauging ... A gauge ( of any suitable form) of metal 1,6 mm thick and having one slot for each size of. Elongation Gauge, Length Gauge - Sun LabTek Elongation Gauge SL-AG-002, Used for determination of elongation index of aggregates. It consists of a steel frame having slots of different dimensions. Classification - M&L Testing Equipment Elongation Index for Classification of Aggregate Particles— H-1682 ... Particle is flaky when its thickness (smallest dimension) is less than 0.6 of the mid-size of the ... (passing appropriate slots) as percent of the sample is the flakiness index. flakiness index - Transportation